Field Testing of RF Meters
Several consumer and inspection grade RF meters were evaluated for accuracy and usability.
For all the tests, a Holaday HI-3004EX with HSE probe was used as a primary reference. This meter and probe
combination was recently calibrated at the factory, and the frequency specific probe calibration factors were
applied to all results. For most tests, a location was selected where the field was relatively homogenous
(not close to the ground or other objects that would produce reflections). This was not laboratory testing, and
absolute accuracy is not claimed, but it does represent real-world product usage conditions. Further information
on the testing process, along with site photos, will be coming soon. Descriptive comments, features, and photos
for all meters tested will also be added, and new meters will be tested as time and availability permit.
All readings in V/m
(*converted from instrument native units)
|
Location |
Dominant Frequency (MHz) |
Holaday (reference) |
Narda * (2nd reference) |
EMC - T&D Smart Fieldmeter |
Gigahertz Solutions HF-38B * |
HF Detector II Profi * | AlphaLab RF Meter * |
|
Cell Site |
860 |
0.42 |
X |
0.35 |
0.350 |
0.21 |
2.0 |
| " |
860 |
1.40 |
X |
1.10 |
overange |
0.68 |
6.7 |
|
FM Tower |
100 |
4.00 |
4.2 |
4.00 |
overange |
2.70 |
7.3 |
|
Walkie Talkie in Office |
462 |
1.20 |
X |
1.00 |
overange |
0.34 |
3.4 |
| " |
462 |
3.60 |
4.0 |
3.60 |
overange |
2.70 |
16.2 |
|
TDMA Cell Phone (pulsed) |
840 |
1.40 |
X |
1.10 |
overange |
0.95 |
3.4 |
|
Average % error |
N/A |
Ref. |
Ref. |
13% |
Insufficient Data |
45% |
252% |
RF Meters Tested
 |
EMC - T&D Smart Fieldmeter
Descriptive Comments Here
|
 |
GigahertzSolutions HF-38B
Descriptive Comments Here
|
 |
HF Detector II Profi
Descriptive Comments Here
|
 |
AlphaLab RF Meter
Descriptive Comments Here
|
RF Measurements and Cell Tower Testing
EMF Services
6481 Aragon Way #305
Fort Myers, Florida 33912
941-870-5432
(Outside the U.S. 239-209-1418)
FAX 866-785-3903
emf-info@emfservices.com
Providing Services Nationwide from locations in Florida and California
Home |
Services |
Profile |
EMF News |
History |
FAQs |
Links
Site contents Copyright
© 2008.
|